DocumentCode :
3021438
Title :
Testing of a one dimensional model for Field II calibration
Author :
Bak, Dominik ; Jensen, Jørgen Arendt ; Willatzen, Morten
Author_Institution :
Dept. of Electr. Eng., Tech. Univ. of Denmark
fYear :
2008
fDate :
2-5 Nov. 2008
Firstpage :
1417
Lastpage :
1420
Abstract :
Field II is a program for simulating ultrasound transducer fields. It is capable of calculating the emitted and pulse-echoed fields for both pulsed and continuous wave transducers. To make it fully calibrated a model of the transducer´s electro-mechanical impulse response must be included. We examine an adapted one dimensional transducer model originally proposed by Willatzen to calibrate Field II. This model is modified to calculate the required impulse responses needed by Field II for a calibrated field pressure and external circuit current calculation. The testing has been performed with Pz27 piezoceramic discs from Ferroperm Piezoceramics A/S, Kvistgaard, Denmark. The transmitted acoustic pressures from two sets of each five disc samples with 10.08 mm diameters were measured in an automatic water bath needle hydrophone setup together with the current flow through the driving circuit. Resonance frequencies at 2.1 MHz and 4 MHz were applied. Two types of circuits were considered, one circuit with a simple resistance load of 47.5 Omega and one with an example of a LR tuning circuit typically found in commercial transducers. The measurements were averaged 128 times and afterwards compared to the calibrated Field II program for 1, 4, and 10 cycle excitations. Two parameter sets were applied for modeling, one real valued Pz27 parameter set, manufacturer supplied, and one complex valued parameter set found in literature, Alguero et al.. The latter implicitly accounts for attenuation. Results show that the combination of the model and Field II can calculate the pressure within -15% to 5% RMS error for long excitation bursts and 7% to 23% for short excitation bursts. Furthermore it is shown that current simulations can be done within 1% to maximum 33% RMS error, where best current simulations are found for 4 MHz long burst simulations and worst case is found for 2.1 MHz short bursts. Finally it is shown that maximum pressure deviation for the real parameter set and the - - complex parameter simulation is 3% for pressure and 5.3% for current.
Keywords :
calibration; electromechanical effects; testing; ultrasonic transducers; 1D model testing; Field II calibration; Pz27 piezoceramic discs; continuous wave transducers; electromechanical impulse response; external circuit current calculation; frequency 2.1 MHz; pulsed wave transducers; ultrasound transducer field simulation; water bath needle hydrophone; Acoustic measurements; Acoustic testing; Calibration; Circuit testing; Current measurement; Electrical resistance measurement; Performance evaluation; Piezoelectric materials; Ultrasonic imaging; Ultrasonic transducers;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Ultrasonics Symposium, 2008. IUS 2008. IEEE
Conference_Location :
Beijing
Print_ISBN :
978-1-4244-2428-3
Electronic_ISBN :
978-1-4244-2480-1
Type :
conf
DOI :
10.1109/ULTSYM.2008.0344
Filename :
4803407