DocumentCode
3021577
Title
Influence of the transducer geometry on the phase of the signal used for reducing second harmonic during ultrasound propagation
Author
Pasovic, Mirza ; Matte, Guillaume ; Van der Steen, Antonius F W ; Basset, Olivier ; De Jong, Nico ; Cachard, Christian
Author_Institution
CREATIS-LRMN, Univ. de Lyon, Lyon
fYear
2008
fDate
2-5 Nov. 2008
Firstpage
1290
Lastpage
1293
Abstract
Ultrasound contrast harmonic imaging is one of the most used contrast detection method in common system used for diagnostic. Its success comes from the higher non linearity properties of ultrasound contrast agents compared to tissue. A way to further enhance agent to tissue ratio would be to locally suppress second harmonic that is generated due to non linear propagation in tissue. Reducing higher harmonics from surrounding medium is a challenge that has been previously studied. Christopher proposed to transmit inverted replica of back propagated signal, Krishnan, back propagated only second harmonic and added inverted replica of it to excitation, Shen proposed transmitting third harmonic to reduce the second harmonic. In our study, a custom made dual frequency phased array transducer, is used to transmit 2 different signals: the imaging signal and the Second Harmonic Reduction Signal (SHRS). In this paper we study the what is optimal phase PhiSHRS 0 of SHRS needed to achieve a maximum 2nd harmonic frequency reduction in a region of interest, depending upon the several properties of transducer apertures.We have observed that as the size of the transducer and focal distance changes, also the optimal phase of the signal used for reducing the 2nd harmonic changes. If the phase of the signal is inappropriate, increase of the 2nd harmonic can be observed rather than decrease.
Keywords
biological tissues; biomedical ultrasonics; ultrasonic imaging; ultrasonic propagation; ultrasonic transducers; biological tissue; dual frequency phased array transducer; focal distance; nonlinear ultrasonic propagation; second harmonic reduction signal; transducer geometry; ultrasound contrast agents; ultrasound contrast harmonic imaging; Apertures; Biomedical engineering; Biomedical imaging; Frequency; Geometry; Phased arrays; Power harmonic filters; Signal processing; Ultrasonic imaging; Ultrasonic transducers;
fLanguage
English
Publisher
ieee
Conference_Titel
Ultrasonics Symposium, 2008. IUS 2008. IEEE
Conference_Location
Beijing
Print_ISBN
978-1-4244-2428-3
Electronic_ISBN
978-1-4244-2480-1
Type
conf
DOI
10.1109/ULTSYM.2008.0312
Filename
4803414
Link To Document