• DocumentCode
    3022739
  • Title

    Method of Extracting Unloaded Q Applied Across Different Resonator Technologies

  • Author

    Ruby, Rich ; Parker, Reed ; Feld, Dave

  • Author_Institution
    Wireless Semicond. Div., Avago Technol., San Jose, CA
  • fYear
    2008
  • fDate
    2-5 Nov. 2008
  • Firstpage
    1815
  • Lastpage
    1818
  • Abstract
    When comparing different resonator technologies, it is essential that fundamental properties such as the unloaded Q be accurately portrayed. Important Figure-of-Merit (FOM) numbers for resonators include operating frequency, coupling coefficient (kt2), Q, and the products - - kt2*Q and f*Q. Three of the five Figure´s of Merit depend on an accurate evaluation of unloaded Q. Using a new equation for Q (derived from first principles), we can measure both Q and the coupling coefficient for a variety of resonator technologies and compare the relative performance metrics of each technology.
  • Keywords
    Q-factor; acoustic resonators; ultrasonic devices; Figure-of-Merit numbers; coupling coefficient; operating frequency; resonator technologies; unloaded Q extraction; Band pass filters; Cellular phones; Electrical resistance measurement; Equations; Film bulk acoustic resonators; Q measurement; Resonance; Resonant frequency; Resonator filters; Scattering parameters;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Ultrasonics Symposium, 2008. IUS 2008. IEEE
  • Conference_Location
    Beijing
  • Print_ISBN
    978-1-4244-2428-3
  • Electronic_ISBN
    978-1-4244-2480-1
  • Type

    conf

  • DOI
    10.1109/ULTSYM.2008.0446
  • Filename
    4803460