    Comparison of ultrasound strain images with multi-modality imaging techniques in liver RF ablation assessment: Initial ex vivo and clinical results

  • Author

    Fernandez, Anna T. ; Kolokythas, Orpheus ; Gauthier, Thomas ; Herzka, Daniel A. ; Patil, Abhay V. ; Xie, Hua

  • Author_Institution
    Philips Res. North America, Briarcliff Manor, NY
  • fYear
    2008
  • fDate
    2-5 Nov. 2008
  • Firstpage
    313
  • Lastpage
    316
  • Abstract
    Ultrasound (US) elastography in liver imaging applications has recently gained interest in the clinical community. Various techniques explore the use of elasticity information for clinical diagnosis (for fibrosis-cirrhosis staging) and assessment of radiofrequency (RF) or High Intensity Focused Ultrasound (HIFU) ablation. In this paper, we conduct compression-based strain imaging for ex vivo and clinical liver RF ablation (RFA) assessment, using the RFA needle to induce the strain (method initially proposed by Varghese et al. in ex vivo porcine). The results are validated against several imaging modalities. Six ex vivo bovine livers were embedded in gelatin mixtures. A commercial RFA needle (Rita) was inserted and deployed into each liver sample. Radiofrequency (RF) ultrasound data were collected using Philips US systems during RFA needle pulling. Strain images were generated offline using 2D speckle tracking. Post- RFA strain images were compared to T1-weighted MRI (Philips). The livers were then dissected along the US image plane for caliper measurements. The elasticity images of the lesions exhibit a 40-fold contrast-to-noise Ratio (CNR) enhancement as compared to B-mode. The lesion sizes, as measured on the elasticity images, compared well with the MRI measurements (<10% error). Clinical RF data were acquired on two RFA patients with an iU-22 system (Philips). Both patients underwent pre- and post-operative contrast computed tomograpy (CT) imaging, and one also had intra-operative contrastenhanced ultrasound. Following RFA, no lesion could be clearly identified in the US B-mode images. Comparable lesion dimensions were measured from the intra-operative elasticity images and post-operative contrast CT. Elasticity imaging could provide similar information as contrast CT or contrast ultrasound imaging without the need for contrast or additional ionizing radiation. It also potentially allows for intra-operative monitoring of the RFA procedure, which in turn coul- - d lead to improved efficacy of RFA treatments.
  • Keywords
    biomechanics; biomedical ultrasonics; elasticity; liver; radiation therapy; radiofrequency heating; ultrasonic imaging; 2D speckle tracking; HIFU ablation; RFA needle; T1 weighted MRI comparison; bovine livers; clinical diagnosis; compression based strain imaging; contrast computed tomograpy imaging; contrast enhanced ultrasound imaging; fibrosis-cirrhosis staging; gelatin mixtures; high intensity focused ultrasound; liver RF ablation assessment; liver elasticity information; liver imaging applications; multimodality imaging techniques; radiofrequency ablation; ultrasonic elastography; ultrasound strain images; Capacitive sensors; Computed tomography; Elasticity; Lesions; Liver; Magnetic resonance imaging; Needles; Radio frequency; Ultrasonic imaging; Ultrasonic variables measurement; RF ablation; contrast-CT; speckle-tracking; therapy assessment; ultrasound elasticity imaging;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Ultrasonics Symposium, 2008. IUS 2008. IEEE
  • Conference_Location
    Beijing
  • Print_ISBN
    978-1-4244-2428-3
  • Electronic_ISBN
    978-1-4244-2480-1
  • Type

    conf

  • DOI
    10.1109/ULTSYM.2008.0077
  • Filename
    4803482