• DocumentCode
    3023655
  • Title

    Camera mathematic model of the molten steel level detection in the strip casting process

  • Author

    Li Jia-dong ; Wang Zhao-dong ; Wang Kun ; Wang Guo-dong

  • Author_Institution
    State Key Lab. of Rolling & Autom., Northeastern Univ., Shenyang, China
  • fYear
    2013
  • fDate
    20-22 Dec. 2013
  • Firstpage
    1216
  • Lastpage
    1219
  • Abstract
    A CCD system was designed to detect the molten steel level in the strip casting process. According to the image computing method, camera mathematic model of the molten steel level detection was established. Then an experiment was carried out to calibrate the model parameters and the precision of the mathematic model was tested. The result illustrates that the camera mathematic model and calibrate method of the molten steel level are feasible, which show high levels of precision and can be applied in the industrial line for the strip casting.
  • Keywords
    CCD image sensors; calibration; cameras; casting; image processing; liquid metals; mathematical analysis; object detection; production engineering computing; steel; CCD system; calibrate method; camera mathematic model; image computing method; industrial line; model parameters calibration; molten steel level detection; strip casting process; Cameras; Casting; Charge coupled devices; Mathematical model; Steel; Strips; image calibrate; linear CCD; linear translation; molten steel level; twin-roll strip casting;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Mechatronic Sciences, Electric Engineering and Computer (MEC), Proceedings 2013 International Conference on
  • Conference_Location
    Shengyang
  • Print_ISBN
    978-1-4799-2564-3
  • Type

    conf

  • DOI
    10.1109/MEC.2013.6885252
  • Filename
    6885252