• DocumentCode
    3034318
  • Title

    SEU Threshold model and its experimental verification

  • Author

    Palomo, F.R. ; Mogollon, J.M. ; Morilla, Y. ; Garcia-Lopez, J. ; Jimenez-Ramos, M.C. ; Labrador, J.A. ; Cortes-Giraldo, M.A. ; Quesada, J.M. ; Aguirre, M.A.

  • Author_Institution
    Electron. Eng. Dept., Sevilla Univ., Sevilla, Spain
  • fYear
    2011
  • fDate
    19-23 Sept. 2011
  • Firstpage
    420
  • Lastpage
    425
  • Abstract
    This work presents a simplified procedure to obtain the ionization profile from SRIM2010 and the Katz radial dose model applied to oxygen ions with kinetic energy from 12 to 18 MeV. Device simulation of Single Event Upsets needs LET(z) and w(z) (linear energy transfer and lateral radius) as inputs. TCAD simulations with the calculated ionization profile of a digital test chip predicts a SEU Threshold. That threshold is experimentally confirmed using the ion microprobe of the Tandem Van de Graaf accelerator at the CNA facility (Spain), validating the ionization model.
  • Keywords
    electronic engineering computing; radiation hardening (electronics); technology CAD (electronics); CNA facility; Katz radial dose model; LET; SEU threshold model; SRIM2010; Spain; TCAD simulations; Tandem Van de Graaf accelerator; device simulation; digital test chip; experimental verification; ion microprobe; ionization model validation; ionization profile; kinetic energy; lateral radius; linear energy transfer; oxygen ions; single-event upsets; Acceleration; Computational modeling; Indexes; Ions; Predictive models; Low energy accelerators; SEU; Spice; TCAD;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Radiation and Its Effects on Components and Systems (RADECS), 2011 12th European Conference on
  • Conference_Location
    Sevilla
  • ISSN
    0379-6566
  • Print_ISBN
    978-1-4577-0585-4
  • Type

    conf

  • DOI
    10.1109/RADECS.2011.6131418
  • Filename
    6131418