DocumentCode
3034723
Title
Performance monitoring of a northern 3.2 kWp grid-connected photovoltaic system
Author
Thevenard, Didier ; Dignard-Bailey, Lisa ; Martel, Sylvain ; Turcotte, Dave
Author_Institution
Numerical Logics Inc., Waterloo, Ont., Canada
fYear
2000
fDate
2000
Firstpage
1711
Lastpage
1714
Abstract
This paper summarizes five years of monitoring of a facade-mounted grid-connected system in Canada´s far North. The system has been in operation since July 1995 and has delivered around 2 MWh of electrical power on an annual basis since then. Climatic and solar radiation conditions at the site are reviewed, and the performance of the system is assessed from a component perspective (PV array, power conditioning unit) and from a global perspective (AC power delivered to the grid, system efficiency, system reliability)
Keywords
monitoring; photovoltaic power systems; power system reliability; solar cell arrays; 3.2 kW; Canada; PV array; climatic conditions; facade-mounted grid-connected system; grid-connected photovoltaic system; performance monitoring; power conditioning unit; solar radiation conditions; system efficiency; system reliability; Arctic; Computerized monitoring; Costs; Educational institutions; Performance analysis; Photovoltaic systems; Power conditioning; Power generation; Sensor arrays; Solar power generation;
fLanguage
English
Publisher
ieee
Conference_Titel
Photovoltaic Specialists Conference, 2000. Conference Record of the Twenty-Eighth IEEE
Conference_Location
Anchorage, AK
ISSN
0160-8371
Print_ISBN
0-7803-5772-8
Type
conf
DOI
10.1109/PVSC.2000.916233
Filename
916233
Link To Document