• DocumentCode
    3043755
  • Title

    An Early Development of Force Distribution Sensor Using Pressure-Sensitive Conductive Rubber for Soft Tissue Balance in Total Knee Arthroplasty

  • Author

    Som, Mohd Hanafi Mat ; Nagamune, Kouki ; Kamiya, Toshio ; Kawaguchi, Shogo ; Matsumoto, Tad ; Kuroda, Rihito ; Kurosaka, Masahiro

  • Author_Institution
    Grad. Sch. of Eng., Univ. of Fukui, Fukui, Japan
  • fYear
    2013
  • fDate
    13-16 Oct. 2013
  • Firstpage
    2556
  • Lastpage
    2560
  • Abstract
    Total knee arthroplasty nowadays becomes a common procedure to restore the knee function for patients who suffered either natural knee diseases or injuries. The procedure effectively reduces pain and improves knee function with high rate of success. However, the risk of failure is still a problem despite this particular issue has been discussed for the past decades by researchers all over the world. The current implementation of the procedures relies heavily on the feel of the surgeons to ensure the right implantation of the prosthesis on the tibiofemoral component. A force distribution measurement system which has a sufficient accuracy for determining the location of tibiofemoral contact forces is being developed to address this concern. The system consisted of two pressure sensitive sensors, embedded in the trial insert for each condyle. The sensors were made up of pressure-conductive rubber with 8 x 16 of electrodes arrays at the front and backside of the rubber. The current study focuses on the reliability and validity of the measurement performed using the developed sensors. The results indicate good response of the rubber against constant applied force within the first two minutes before the measurement error start increasing over time.
  • Keywords
    biomedical electrodes; biomedical measurement; bone; diseases; force sensors; injuries; orthopaedics; pressure sensors; prosthetics; rubber; surgery; condyle trial insert; constant applied force; electrode arrays; failure risk; force distribution measurement system; force distribution sensor; injuries; knee function restoration; measurement error; measurement reliability; measurement validity; natural knee diseases; pain reduction; pressure sensitive sensors; pressure-sensitive conductive rubber; prosthesis implantation; rubber backside; rubber frontside; soft tissue balance; surgeon feeling; tibiofemoral component; tibiofemoral contact force location; total knee arthroplasty; Biological tissues; Electrodes; Force; Force measurement; Force sensors; Rubber; Voltage measurement; Pressure conductive rubber; TKA; soft tissue balance; total knee arthroplasty;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Systems, Man, and Cybernetics (SMC), 2013 IEEE International Conference on
  • Conference_Location
    Manchester
  • Type

    conf

  • DOI
    10.1109/SMC.2013.436
  • Filename
    6722189