• DocumentCode
    3045545
  • Title

    A New High-Sensitivity Package-Leak Testing Method for MEMS Sensors

  • Author

    Fujiyoshi, Masaaki ; Nonomura, Y. ; Senda, H.

  • Author_Institution
    Toyota Central R&D Labs., Inc., Aichi
  • fYear
    2009
  • fDate
    25-29 Jan. 2009
  • Firstpage
    737
  • Lastpage
    740
  • Abstract
    A new high-sensitivity package-leak testing method has been developed for micro electro mechanical system (MEMS) sensors such as a vibrating angular-rate sensor housed in a vacuum package. Procedures of the method to obtain high leak-rate resolution are as follows. (1) A package filled with helium gas is kept in a small and closed chamber to accumulate helium gas leaking out of the package. (2) The chamber is chilled with liquid-N2 after the accumulation to reduce background gases except the helium gas. (3) The helium gas is transported to a mass spectrometer in a short time and recorded as a transient waveform. The leak-rate resolution of 1times10-17 Pamiddotm3/s was obtained. This resolution was 105 times superior to that of the conventional method.
  • Keywords
    electronics packaging; helium; mass spectrometers; microsensors; He; MEMS sensor; angular-rate sensor; high-sensitivity package-leak testing method; leak-rate resolution; mass spectrometer; microelectromechanical system sensor; vacuum package; Gases; Helium; Mass spectroscopy; Mechanical sensors; Mechanical systems; Micromechanical devices; Packaging; Sensor systems; System testing; Vacuum systems;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Micro Electro Mechanical Systems, 2009. MEMS 2009. IEEE 22nd International Conference on
  • Conference_Location
    Sorrento
  • ISSN
    1084-6999
  • Print_ISBN
    978-1-4244-2977-6
  • Electronic_ISBN
    1084-6999
  • Type

    conf

  • DOI
    10.1109/MEMSYS.2009.4805488
  • Filename
    4805488