DocumentCode
3046861
Title
Thyratron evaluation at high power, high repetition rates
Author
Cavazos, T. ; McGowan, J. ; Behr, S.
Author_Institution
US Army LABCOM-ETDL, Fort Monmouth, NJ, USA
fYear
1990
fDate
26-28 Jun 1990
Firstpage
211
Lastpage
214
Abstract
Two double-gap tubes, the EEV 1536-R and the ITT F-266, were operated at 40 kV and 6 kHz for 100 s bursts at average powers of 600 kW and 1.2 MW. Operations at 10 kHz was also attempted for the two thyratrons. An initiative is planned for the evaluation of a three gap tube, the EEV 1776, at 80 kV, 6 kHz, for 100 s burst operation. The thyratrons were operated in a RLC test circuit to simulate half-sine duty. Reliable operation is achieved by using a saturable inductor in the charging circuit and adjusting the load resistance of the discharging circuit for a 10% voltage reversal on the anode after the tube fires. These techniques combined provide 25 μs to 30 μs for switch recovery after conduction
Keywords
reliability; switchgear; switchgear testing; thyratrons; 100 s; 25 to 30 mus; 40 kV; 6 kHz; 80 kV; EEV 1536-R; EEV 1776; ITT F-266; RLC test circuit; anode; charging circuit; discharging circuit; load resistance; reliability; repetition rates; saturable inductor; switch recovery; switchgear; testing; thyratrons; voltage reversal; Anodes; Barium; Circuit testing; Electrodes; Heating; Petroleum; RLC circuits; Switches; Thyratrons; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Power Modulator Symposium, 1990., IEEE Conference Record of the 1990 Nineteenth
Conference_Location
San Diego, CA
Type
conf
DOI
10.1109/MODSYM.1990.201060
Filename
201060
Link To Document