DocumentCode
3048306
Title
Bayesian Reconstruction Algorithm for PET Using New Markov Quadratic Hybrid Multi-Order Priors
Author
Zhan, Jie ; Chen, Wufan
Author_Institution
Sch. of Biomed. Eng., Southern Med. Univ., Guangzhou
fYear
2007
fDate
6-8 July 2007
Firstpage
334
Lastpage
337
Abstract
Bayesian reconstruction, or maximum a posteriori (MAP) method, has proved its superiority over others in positron emission tomography (PET) image reconstruction. In this article, a novel type of concave MRF (Markov random fields) hybrid convex priors for Bayesian reconstruction, which combine quadratic smoothness priors of different orders, are proposed. The design of the new priors is based on the intrinsic properties of the smoothness priors of different orders and aims to make an adaptive use of the smoothness priors. Effective parameter estimations are given Simulation experiments of their application in PET reconstruction are illustrated. Results and comparisons proved the new hybrid priors´ good performance in lowering noise effect and preserving edges.
Keywords
Markov processes; biology computing; image reconstruction; medical image processing; positron emission tomography; Bayesian reconstruction algorithm; Markov quadratic hybrid multiorder priors; Markov random fields; PET image reconstruction; concave MRF hybrid convex priors; maximum a posteriori method; positron emission tomography; Bayesian methods; Biomedical engineering; Biomedical imaging; Image reconstruction; Markov random fields; Medical simulation; Parameter estimation; Positron emission tomography; Quadratic programming; Reconstruction algorithms;
fLanguage
English
Publisher
ieee
Conference_Titel
Bioinformatics and Biomedical Engineering, 2007. ICBBE 2007. The 1st International Conference on
Conference_Location
Wuhan
Print_ISBN
1-4244-1120-3
Type
conf
DOI
10.1109/ICBBE.2007.89
Filename
4272573
Link To Document