• DocumentCode
    3049221
  • Title

    Measurement of the harmonic contents of electric signals using FPGA and switched capacitor filters

  • Author

    Naguil, J.L. ; Toledo, E. N Pereyra ; Cova, W. J D

  • Author_Institution
    Inst. Univ. Aeronautico, Cordoba
  • fYear
    2008
  • fDate
    13-15 Aug. 2008
  • Firstpage
    1
  • Lastpage
    6
  • Abstract
    The measurement of the harmonic contents of an electric signal is particularly complex task due to the spectral analysis involved. The present work addresses two basic objectives. The first one is to construct a device capable of carrying out a low error measurement of total harmonic distortion during one cycle of the electric power signal. The second one aims to laying the foundations for embedding the measurement system in an integrated chip.
  • Keywords
    field programmable gate arrays; harmonic distortion; power electronics; power harmonic filters; FPGA; electric power signal; harmonic contents measurement; spectral analysis; switched capacitor filters; total harmonic distortion; Capacitors; Distortion measurement; Electric variables measurement; Field programmable gate arrays; Particle measurements; Power harmonic filters; Power measurement; Semiconductor device measurement; Spectral analysis; Total harmonic distortion; Amplitude harmonic distortion; CORDIC algorithm; FPGA; Goertzel transform; switched capacitor filters;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Transmission and Distribution Conference and Exposition: Latin America, 2008 IEEE/PES
  • Conference_Location
    Bogota
  • Print_ISBN
    978-1-4244-2217-3
  • Electronic_ISBN
    978-1-4244-2218-0
  • Type

    conf

  • DOI
    10.1109/TDC-LA.2008.4641813
  • Filename
    4641813