DocumentCode :
3052284
Title :
Power factor optimization with switched-LC networks
Author :
Montaño, J.C. ; Gutiérrez, J. ; Castilla, M. ; López, A.
Author_Institution :
IRNAS, CSIC, Sevilla, Spain
Volume :
3
fYear :
1996
fDate :
13-16 May 1996
Firstpage :
1555
Abstract :
A new reactive power compensator consisting of a set of parallel LC branches, which can be automatically switched, is proposed. This permits operation under nonsinusoidal conditions and time-varying loads. A control system, which measures the equivalent admittance on the load side, and sets the optimal LC configuration to minimize the reactive component of the line current, has been used. Thus, the synthesized compensator presents an equivalent harmonic-susceptance which is approximately equal (as given by its discrete structure) to that of the load (with opposite sign) within the appropriate frequency range. Numerical simulation and experimental results are presented
Keywords :
compensation; electric admittance measurement; power factor correction; power system harmonics; reactive power; reactors (electric); switched networks; thyristor applications; control system; discrete structure; equivalent admittance measurement; equivalent harmonic-susceptance; line current minimisation; nonsinusoidal conditions; parallel LC branches; power factor optimization; reactive power compensator; switched-LC networks; thyristor controlled reactors; time-varying loads; Admittance; Capacitors; Impedance; Inductance; Inductors; Passive networks; Reactive power; Switches; Tiles; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrotechnical Conference, 1996. MELECON '96., 8th Mediterranean
Conference_Location :
Bari
Print_ISBN :
0-7803-3109-5
Type :
conf
DOI :
10.1109/MELCON.1996.551248
Filename :
551248
Link To Document :
بازگشت