  • Abstract
    An algorithm is presented to detect arrow-shaped skin markers that have been designed for matching of CT and MR images. The markers can be located in the images with subslice accuracy, which allows accurate registration even in standard imaging protocols employing thick slices and/or large interslice gaps. In the past, extracting the marker information from the images has been a highly interactive process. The algorithm described only requires a minimal amount of user interaction
  • Keywords
    biomedical NMR; computerised tomography; image recognition; medical diagnostic computing; CT/MRI fusion; arrow shaped marker detection; computerised tomography; feature extraction; imaging protocols; magnetic resonance imaging; medical computing; pattern recognition; Algorithm design and analysis; Computed tomography; Computer vision; Data mining; Ear; Head; Hospitals; Magnetic resonance imaging; Protocols; Skin;