Abstract :
A De Brujin graph (DBG) model is proposed to apply to enhance communication robustness and to improve energy reliability and efficiency in smart grids. This fault tolerant model can avoid wire communication faults among smart meters by an alternative wireless resilient Zigbee scheme. As a result, this communication model can also search optimized wireless resilience paths to enhance communication fault tolerance. The experimental results show 100% communication fault tolerance in all smart grid regions based on single fault assumption. While for multiple link fault tolerance, our proposed FTGDB scheme could averagely tolerate more than 30% faulty links simultaneously.
Keywords :
Zigbee; carrier transmission on power lines; fault tolerance; graph theory; radio links; smart power grids; telecommunication network reliability; DBG model; De Bruijn graph-based communication modeling; FTGDB scheme; communication fault tolerance; communication robustness; energy reliability; faulty links; multiple link fault tolerance; single fault assumption-based smart grid regions; smart grid efficiency; smart meters; wire communication faults; wireless resilience paths optimization; wireless resilient Zigbee scheme; Fault tolerance; Fault tolerant systems; Power system reliability; Smart grids; Wireless communication; Zigbee;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Circuits and Systems (APCCAS), 2012 IEEE Asia Pacific Conference on
Conference_Location :
Kaohsiung
Print_ISBN :
978-1-4577-1728-4
Type :
conf
DOI :
10.1109/APCCAS.2012.6419112
Filename :
6419112
Link To Document :
بازگشت