DocumentCode
3060939
Title
Experimental comparisons of space vector neutral point balancing strategies for three-level topology
Author
Zhou, Dongsheng ; Rouaud, Didier
Author_Institution
Medium Voltage Div., Rockwell Autom., Mequon, WI, USA
Volume
2
fYear
1999
fDate
1999
Firstpage
1071
Abstract
Three-level neutral point clamp topology has attracted applications in medium-voltage high-power drive systems. Since the topology utilizes the neutral point voltage to achieve half bus voltage withstand of power devices and three-level output voltage delivery, it is critical to balance the neutral point voltage in occasions of disturbed or even continuous unbalance load conditions. This paper proposes a couple of balancing techniques based on space vector modulation principle and experimentally compares their effectiveness against the existing method
Keywords
electric drives; power convertors; continuous unbalance load conditions; disturbed load conditions; half bus voltage withstand; neutral point voltage balancing; space vector modulation; space vector neutral point balancing strategies; three-level neutral point clamp topology; three-level output voltage delivery; three-level topology; Automation; Clamps; Load flow; Medium voltage; Metals industry; Milling machines; Paper mills; Rectifiers; Space technology; Topology;
fLanguage
English
Publisher
ieee
Conference_Titel
Power Electronics Specialists Conference, 1999. PESC 99. 30th Annual IEEE
Conference_Location
Charleston, SC
ISSN
0275-9306
Print_ISBN
0-7803-5421-4
Type
conf
DOI
10.1109/PESC.1999.785644
Filename
785644
Link To Document