• DocumentCode
    3065102
  • Title

    Improved modeling of Faraday cage for electromagnetic compatibility testing

  • Author

    Munic, N.V. ; Stevanovic, M.M. ; Kovacevic, A.M. ; Dordevic, A.R.

  • fYear
    2012
  • fDate
    20-22 Nov. 2012
  • Firstpage
    1115
  • Lastpage
    1118
  • Abstract
    By military standards SORS 1029/89 and SORS 1762/89, electromagnetic-compatibility tests of tools and weapon systems and military equipment of the Serbian Army, are carried out in a Faraday cage, which has many parasitic resonances due to the reflective walls. In order to improve these tests, we modeled a complete Faraday cage. Various imperfections of the cage were detected by comparing results of simulations and experiments, and they were included into the model.
  • Keywords
    electromagnetic compatibility; military equipment; weapons; Faraday cage; SORS 1029/89; SORS 1762/89; Serbian Army; electromagnetic compatibility testing; military equipment; military standards; weapon systems; Antenna measurements; Electromagnetic interference; Measurement uncertainty; NIST; Telecommunications;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Telecommunications Forum (TELFOR), 2012 20th
  • Conference_Location
    Belgrade
  • Print_ISBN
    978-1-4673-2983-5
  • Type

    conf

  • DOI
    10.1109/TELFOR.2012.6419406
  • Filename
    6419406