DocumentCode
3065853
Title
A control method of active power filter in unsymmetrical voltage system
Author
Komatsu, Yasuhiro ; Kawabata, Takao
Author_Institution
Ritsumeikan Univ., Siga, Japan
Volume
2
fYear
1997
fDate
26-29 May 1997
Firstpage
839
Abstract
In this paper, the authors propose a calculation method for compensating the current reference of an active power filter, where a nonlinear load exists in a three-phase three-wire asymmetrical voltage system. This new method has been named the extension pq method. The authors have experimented with the extension pq method and the pq method, using the same current controlled IPM inverter for both methods. The results of the experiments proved that in an asymmetrical voltage system, the source current was distorted in the case of the pq method, but was not distorted in the case of the extension pq method
Keywords
active filters; compensation; harmonic distortion; load (electric); power convertors; power filters; power system harmonics; IPM inverter; active power filter; current reference compensation; diode bridge rectifier; extension pq method; nonlinear load; three-phase three-wire asymmetrical power system; Active filters; Control systems; Equations; IEC; Inverters; Nonlinear control systems; Nonlinear distortion; Proposals; Reactive power; Voltage control;
fLanguage
English
Publisher
ieee
Conference_Titel
Power Electronics and Drive Systems, 1997. Proceedings., 1997 International Conference on
Print_ISBN
0-7803-3773-5
Type
conf
DOI
10.1109/PEDS.1997.627504
Filename
627504
Link To Document