DocumentCode
3068696
Title
Comparison of several HEMP waveform standards
Author
Yan-Zhao, Xie ; Zan-Ji, Wang ; Qun-Shu, Wang ; Hui, Zhou
Author_Institution
Dept. of Electr. Eng., Tsinghua Univ., Beijing, China
fYear
2004
fDate
24-27 Aug. 2004
Firstpage
516
Lastpage
518
Abstract
There exist different effect results for the susceptibility of equipment and systems due to the change of high altitude nuclear electromagnetic pulse (HEMP) waveform standards. These standards can be classified into three types, long duration (Publication 1 in 1976), medium duration (Bell Laboratory) and short duration (IEC61000-2-9). Time domain parameters, amplitude spectrum, and the cumulative energy fluence of these HEMP waveforms are compared.
Keywords
electromagnetic pulse; immunity testing; standards; HEMP waveform standards; amplitude spectrum; cumulative energy fluence; high altitude nuclear electromagnetic pulse waveform standards; long duration pulse standards; medium duration pulse standards; short duration pulse standards; susceptibility testing; time domain parameters; EMP radiation effects; Frequency; IEC standards; Laboratories; Marine vehicles; Standards publication; Superluminescent diodes; System testing; Tin; US Department of Defense;
fLanguage
English
Publisher
ieee
Conference_Titel
Radio Science Conference, 2004. Proceedings. 2004 Asia-Pacific
Print_ISBN
0-7803-8404-0
Type
conf
DOI
10.1109/APRASC.2004.1422538
Filename
1422538
Link To Document