DocumentCode :
3070416
Title :
Operation of PMSM after single open-phase fault
Author :
Kontarcek, Andraz ; Bajec, Primoz ; Nemec, M. ; Ambrozic, V.
Author_Institution :
Hidria Rotomatika d.o.o., Slovenia
fYear :
2013
fDate :
5-7 June 2013
Firstpage :
177
Lastpage :
181
Abstract :
Recently, the reliability and safety of electrical drives became very important, especially in critical applications, such as in automotive, aerospace and military industry. For such systems, it is desirable to detect and identify different kind of faults and, if possible, to continue operating after the fault occurs. After single open-phase fault is detected and identified, it is desirable to continue operating with reduced power. In this paper, modified direct torque control method for post-fault operation of permanent magnet synchronous motor is presented, without the need of changing the topology of power converter. In order to avoid negative torque operation, pre-firing angle is also introduced. The proposed method has been simulated and tested in Matlab/Simulink.
Keywords :
electrical safety; fault diagnosis; firing (materials); machine control; permanent magnet motors; power convertors; reliability; synchronous motor drives; torque control; Matlab-Simulink simulation; PMSM; aerospace industry; automotive industry; electrical drive; military industry; modified direct torque control method; negative torque operation; permanent magnet synchronous motor; post-fault operation; power converter; pre-firing angle; reliability; safety; single open-phase fault detection; Circuit faults; Fault tolerance; Fault tolerant systems; Switches; Topology; Torque; Vectors;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Compatibility and Power Electronics (CPE), 2013 8th International Conference on
Conference_Location :
Ljubljana
ISSN :
2166-9538
Print_ISBN :
978-1-4673-4911-6
Type :
conf
DOI :
10.1109/CPE.2013.6601150