DocumentCode :
3070647
Title :
Evaluation of simplified dq model of induction machine for development of diagnostic procedures
Author :
Nemec, M. ; Drobnic, K. ; Lavric, H. ; Ambrozic, V.
Author_Institution :
Univ. of Ljubljana, Ljubljana, Slovenia
fYear :
2013
fDate :
5-7 June 2013
Firstpage :
250
Lastpage :
254
Abstract :
This paper presents evaluation of simplified dq model of induction machine. Model is particularly useful for simulation of induction machines with broken rotor bars. Investigation is made in how useful and accurate this model is compared to experimental measurements. Comparison of simulation results with experimental data, don for two different machines, show that the model is very accurate and useful. Along with its fast execution speed it makes a good foundation for further development of advanced detection and diagnostic techniques.
Keywords :
asynchronous machines; rotors; advanced detection techniques; broken rotor bars; diagnostic procedures; execution speed; induction machines; simplified dq model; Bars; Current measurement; Induction machines; Load modeling; Mathematical model; Rotors; Stators;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Compatibility and Power Electronics (CPE), 2013 8th International Conference on
Conference_Location :
Ljubljana
ISSN :
2166-9538
Print_ISBN :
978-1-4673-4911-6
Type :
conf
DOI :
10.1109/CPE.2013.6601164
Filename :
6601164
Link To Document :
بازگشت