DocumentCode :
3071544
Title :
Behaviour of streamers under divergent AC fields in transformer oils at large gaps
Author :
Rain, P. ; Boisdon, C. ; Lesaint, O. ; Tobazeon, R.
Author_Institution :
Jeumont-Schneider Transformateurs, Lyon, France
fYear :
1990
fDate :
10-14 Sep 1990
Firstpage :
425
Lastpage :
429
Abstract :
Measurements of streamer lengths in transformer oils under various divergent AC fields and at large gaps (⩽8 cm) have been conducted. Positive streamers play a dominant role in breakdown since their propagation lengths are much larger than those of negative ones. Several configurations of electrodes have been investigated and some geometrical effects have been found. Specifically, the positive streamers stop at a length which depends not only on the initiation voltage, but also significantly on the geometry (distance and shape of electrodes)
Keywords :
electric breakdown of liquids; electric fields; insulating oils; transformer insulation; 8 cm; breakdown; divergent AC fields; electrodes configuration; geometrical effects; initiation voltage; large gaps; positive streamers; propagation lengths; streamer length measurements; streamers; transformer oils; Electric breakdown; Length measurement; Oil insulation; Petroleum; Power transformer insulation; Relays; Solid state circuits; Streaming media; Visualization; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Conduction and Breakdown in Dielectric Liquids, 1990. ICDL 1990. Conference Record., 10th International Conference on
Conference_Location :
Grenoble
Type :
conf
DOI :
10.1109/ICDL.1990.202937