• DocumentCode
    3072938
  • Title

    Synthesis of a closed loop transfer function with aid of finite Hilbert transforms

  • Author

    Gera, A.E.

  • Author_Institution
    Elta Electronics Industries Ltd., Ashdod, Israel
  • fYear
    1986
  • fDate
    10-12 Dec. 1986
  • Firstpage
    25
  • Lastpage
    30
  • Abstract
    The objective of satisfying assigned performance tolerances over given ranges of plant uncertainty and external disturbances is achieved by synthesis of the closed-loop transmission function L(??) along frequency dependent, boundaries ??(??n) within the Nichols chart. The corresponding frequency bandlimited equations are recognized as those of Carleman. Their solutions are given by closed form expressions involving finite Hilbert integrals. Some numerical examples of such solutions are then presented.
  • Keywords
    Tellurium; Tin; Transfer functions;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Decision and Control, 1986 25th IEEE Conference on
  • Conference_Location
    Athens, Greece
  • Type

    conf

  • DOI
    10.1109/CDC.1986.267126
  • Filename
    4048699