• DocumentCode
    3073592
  • Title

    Detection of micro defects in 3dic packages by means of non-destructive 3D X-ray

  • Author

    Mei-Chin Lee ; Wan-Ting Chen ; Chun-Tang Lin ; Ming-Hsien Yang ; Jeng-Yuan Lai

  • Author_Institution
    Siliconware Precision Ind. Co., Ltd., Taichung, Taiwan
  • fYear
    2012
  • fDate
    24-26 Oct. 2012
  • Firstpage
    209
  • Lastpage
    211
  • Abstract
    In semiconductor assembly, destructive cross-section observation is the mainstream of defects analysis method, the issues that are making destructive analytical methods to be changed are more tedious and time consuming, because it might cause higher risk of creating artifacts. Nevertheless, advanced 3D x-ray technology enables to substitute the destructive analysis and provides the non-destructive detection of defects in 3DIC packages. The key challenge in its general operation principle is data acquisition time. This paper reviews the x-ray computed tomography method (CT scan) for non-destructive micro defects in 3DIC packages. The results have proved that 2D x-ray imaging capabilities is limited and the comparison in 3D x-ray operation principle between microscope and projection based imaging capabilities at micrometer resolution is practiced as a fine method to possibly observe defect shape, size and distribution by conducting the virtual cross-section at desired location. Based on the provided details of defect analysis, 3D x-ray works as a good method to provide non-destructive detect for 3DIC package applications.
  • Keywords
    X-ray microscopy; assembling; computerised tomography; integrated circuit packaging; integrated circuit testing; nondestructive testing; three-dimensional integrated circuits; 2D X-ray imaging; 3DIC package; X-ray computed tomography method; data acquisition time; defects analysis method; destructive analytical method; destructive cross-section observation; microdefect detection; micrometer resolution; microscope; nondestructive 3D X-ray; nondestructive detection; nondestructive microdefect; projection based imaging capability; semiconductor assembly; Computed tomography; Detectors; Failure analysis; IEEE catalog; Solid modeling; X-ray imaging;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Microsystems, Packaging, Assembly and Circuits Technology Conference (IMPACT), 2012 7th International
  • Conference_Location
    Taipei
  • ISSN
    2150-5934
  • Print_ISBN
    978-1-4673-1635-4
  • Electronic_ISBN
    2150-5934
  • Type

    conf

  • DOI
    10.1109/IMPACT.2012.6420261
  • Filename
    6420261