Title :
Image based diagnosis of cortical cataract
Author :
Li, Huiqi ; Ko, Liling ; Lim, Joo Hwee ; Liu, Jiang ; Wong, Damon Wing Kee ; Wong, Tien Yin
Author_Institution :
Institute for Infocomm Research, A*STAR, 21 Heng Mui Keng Terrace, Singapore 119613
Abstract :
An automatic approach to detect cortical opacities and grade the severity of cortical cataract from retro-illumination images is proposed. The spoke-like feature of cortical opacity is employed to separate from other opacity type. The proposed algorithms were tested by images from a community study. The success rate of region of interest (ROI) detection is 98.2% for 611 images. For 466 images tested, the mean error of opacity area detection is 3.15% compared with human grader and 85.6% of exact cortical cataract grading is obtained. The experimental results show that the proposed approach is promising in clinical diagnosis.
Keywords :
Aging; Blindness; Clinical diagnosis; Humans; Image analysis; Lab-on-a-chip; Lenses; Protocols; Testing; Algorithms; Cataract; Diagnostic Techniques, Ophthalmological; Humans; Image Processing, Computer-Assisted; Lens, Crystalline; Observer Variation; Pupil; Reproducibility of Results; Visual Acuity;
Conference_Titel :
Engineering in Medicine and Biology Society, 2008. EMBS 2008. 30th Annual International Conference of the IEEE
Conference_Location :
Vancouver, BC
Print_ISBN :
978-1-4244-1814-5
Electronic_ISBN :
1557-170X
DOI :
10.1109/IEMBS.2008.4650063