DocumentCode :
3084067
Title :
Disturbance assessment in the grid integration of power electronic devices and other non-linear loads
Author :
Yang, X.
Author_Institution :
Electricite de France, France
fYear :
2008
fDate :
10-13 Dec. 2008
Firstpage :
1
Lastpage :
7
Abstract :
Two main grid access contracts have been set up in France between utilities and customers. These grid connection contracts not only fix power quality commitments for grid operators but also customer disturbance emission limits. The practice of these contracts shows that a good overall power quality can only be achieved by respecting commitments and doing effort from both of grid and customer sides. Since the beginning of the 1990´s, a substantial growth of power electronic application has been noticed in electric power systems. More and more power electronic devices have been used in grid and facilities such as low voltage electronic devices (compact fluorescent lamp, switching-mode power supply), adjustable speed drive (ASD), high voltage direct current link (HVDC), etc. The application of power electronic devices in facilities has brought both advantages (energy saving) and side-effects (disturbances). The second part of this paper deals with disturbance load modelling and grid disturbance assessment. For grid disturbance assessment, it is suggested to use multi-phase harmonic injection method with fundamental power flow. This method can give an acceptable results with very short computing time for non linear load modelling. The key point of proposed frequency domain method is that each harmonic source is individually considered as both disturbance source and disturbance receiver in order to take into account interactions between sources. A plug&play HVDC component has been developed and used in one of two case studies in the end of this article.
Keywords :
fluorescent lamps; load flow; power electronics; power grids; power supply quality; adjustable speed drive; compact fluorescent lamp; electric power systems; grid access contracts; grid connection contracts; grid disturbance assessment; grid integration; grid operators; harmonic source; high voltage direct current link; multiphase harmonic injection method; nonlinear loads; power electronic devices; power flow; power quality commitments; side-effects; switching-mode power supply; Contracts; Fluorescent lamps; HVDC transmission; Load modeling; Low voltage; Power electronics; Power quality; Power system harmonics; Power systems; Variable speed drives; Frequency domain modelling; HVDC; Power quality commitment; harmonic; power electronic device;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electricity Distribution, 2008. CICED 2008. China International Conference on
Conference_Location :
Guangzhou
Print_ISBN :
978-1-4244-3373-5
Electronic_ISBN :
978-1-4244-3372-8
Type :
conf
DOI :
10.1109/CICED.2008.5211809
Filename :
5211809
Link To Document :
بازگشت