DocumentCode
3084656
Title
Improvement of automated detection method of hemorrhages in fundus images
Author
Hatanaka, Yuji ; Nakagawa, Toshiaki ; Hayashi, Yoshinori ; Hara, Takeshi ; Fujita, Hiroshi
Author_Institution
Department of Electronic Systems Engineering, School of Engineering, University of Shiga Prefecture, Hassaka-cho 2500, Hikone-shi, 522-8533, Japan
fYear
2008
fDate
20-25 Aug. 2008
Firstpage
5429
Lastpage
5432
Abstract
This paper describe an improved method for detecting hemorrhages in fundus images. The detection of hemorrhages is one of the important factors in the early diagnosis of diabetic retinopathy. So, we had suggested several methods for detecting abnormalities in fundus images, but our methods had some problems. We propose a new method for preprocessing and false positive elimination in the present study. The brightness of the fundus image was changed by the nonlinear curve with brightness values of the hue saturation value (HSV) space. In order to emphasize brown regions, gamma correction was performed on each red, green, and blue-bit image. Subsequently, the histograms of each red, blue, and blue-bit image were extended. After that, the hemorrhage candidates were detected using density analysis. Finally, false positives were removed by using rule-based method and 3 Mahalanobis distance classifiers with a 45-feature analysis. To evaluate the new method for the detection of hemorrhages, we examined 125 fundus images, including 35 images with hemorrhages and 90 normal images. The sensitivity and specificity for the detection of abnormal cases were 80% and 80%, respectively.
Keywords
Biomedical imaging; Brightness; Diabetes; Hemorrhaging; Hospitals; Lesions; Medical diagnostic imaging; Region 5; Retina; Retinopathy; Algorithms; Diabetic Retinopathy; Fluorescein Angiography; Humans; Image Enhancement; Image Interpretation, Computer-Assisted; Pattern Recognition, Automated; Reproducibility of Results; Retina; Retinal Hemorrhage; Retinoscopy; Sensitivity and Specificity;
fLanguage
English
Publisher
ieee
Conference_Titel
Engineering in Medicine and Biology Society, 2008. EMBS 2008. 30th Annual International Conference of the IEEE
Conference_Location
Vancouver, BC
ISSN
1557-170X
Print_ISBN
978-1-4244-1814-5
Electronic_ISBN
1557-170X
Type
conf
DOI
10.1109/IEMBS.2008.4650442
Filename
4650442
Link To Document