Title :
Flexible Sensors Based on Radiation-Induced Diffusion of Ag in Chalcogenide Glass
Author :
Dandamudi, P. ; Mahmud, A. ; Gonzalez-Velo, Y. ; Kozicki, M.N. ; Barnaby, H.J. ; Roos, B. ; Alford, T.L. ; Ailavajhala, M. ; Mitkova, M. ; Holbert, K.E.
Author_Institution :
Sch. of Electr., Arizona State Univ., Tempe, AZ, USA
Abstract :
In this paper, previous work on chalcogenide-glass (ChG)-based radiation sensors is extended to include the effects of mechanical strain and temperature stress on sensors formed on a flexible polymer substrate. We demonstrate the feasibility of producing inexpensive flexible radiation sensors, which utilize radiation-induced migration of Ag+ ions in germanium selenide ( Ge20Se80) films to produce a decrease in resistance of several orders of magnitude between surface electrodes. This change in resistance can be related to total ionizing dose to give an instantaneous readout of radiation exposure. The ChG films are inherently flexible and this, along with an extremely simple device fabrication process at or near room temperature, allows inexpensive sensor structures to be fabricated on lightweight pliable polymeric substrates such as polyethylene napthalate (PEN). Test samples were irradiated with ionizing radiation (UV light and 60 Cobalt gamma rays). Irradiated samples were subjected to both tensile and compressive stress, and elevated operating temperatures. Stress and exposure to increased ambient temperature had little effect on device resistance. Analysis of the experimental data is supported by the results of COMSOL simulations that model radiation-induced lateral Ag diffusion in ChG.
Keywords :
chalcogenide glasses; diffusion; electric resistance; flexible electronics; germanium compounds; internal stresses; particle detectors; semiconductor counters; semiconductor growth; semiconductor thin films; silver; COMSOL simulations; Ge20Se80:Ag; chalcogenide-glass films; chalcogenide-glass-based radiation sensors; compressive stress; device fabrication process; device resistance; flexible polymer substrate; flexible radiation sensors; germanium selenide films; instantaneous readout; lightweight pliable polymeric substrates; mechanical strain effect; operating temperatures; polyethylene napthalate; radiation exposure; radiation-induced lateral Ag diffusion; radiation-induced migration; silver ions; surface electrodes; temperature stress effect; tensile stress; total ionizing dose; Dosimetry; Gamma-rays; Glass; Ionizing radiation sensors; Silver; Thin films; Ultraviolet sources; Chalcogenide glass; UV; dosimetry; flexible radiation sensor; gamma rays; polyethylene napthalate (PEN);
Journal_Title :
Nuclear Science, IEEE Transactions on
DOI :
10.1109/TNS.2014.2364140