Title : 
The Design and Optimization of a 25 kS/s 10 bit Micropower Current S/H Cell for Weak Current Bio-medical Applications
         
        
            Author : 
Tsang, Ka Leong ; Yuan, Jie
         
        
            Author_Institution : 
Hong Kong Univ. of Sci. & Technol., Hong Kong
         
        
        
        
        
        
            Abstract : 
In this paper, a micropower current sample-and-hold front-end is designed for weak current bio-medical applications in a 0.35-mum standard CMOS process. The design reduces the distortion of the current-mode sample-and-hold stage by exploiting the exponential I-V relationship of weakly-inverted MOS transistors. The design and optimization process for the stage is introduced in the paper. With the optimized design, SPICE simulation shows that the sample-and-hold stage can achieve over 60 dB SNDR at the sampling rate of 25 kS/s, with the input signal at the Nyquist frequency of 12.4 kHz. The input current range is 100 nA. The power consumption of the stage is about 3.6 muW.
         
        
            Keywords : 
CMOS analogue integrated circuits; MOSFET; SPICE; biomedical electronics; lab-on-a-chip; sample and hold circuits; CMOS process; I-V relationship; SPICE simulation; current 100 nA; frequency 12.4 kHz; lab-on-chip diagnostics; micropower current S-H cell; optimization process; power 3.6 muW; sample-and-hold front-end; size 0.35 mum; weak current bio-medical applications; weakly-inverted MOS transistors; Application software; DNA; Design optimization; Electrodes; Electronic equipment testing; Energy consumption; MOSFETs; Process design; Radiofrequency interference; Signal design;
         
        
        
        
            Conference_Titel : 
Electronic Design, Test and Applications, 2008. DELTA 2008. 4th IEEE International Symposium on
         
        
            Conference_Location : 
Hong Kong
         
        
            Print_ISBN : 
978-0-7695-3110-6
         
        
        
            DOI : 
10.1109/DELTA.2008.121