• DocumentCode
    3091100
  • Title

    Commissioning of an AMR Prototype System by PLC Technology

  • Author

    Haghgoo, Soodeh ; Monsef, Hasan

  • Author_Institution
    Dept. of Electtical & Comput. Eng., Central Branch of Azad Univ., Tehran
  • fYear
    2007
  • fDate
    24-28 June 2007
  • Firstpage
    1
  • Lastpage
    7
  • Abstract
    In 1980, the novel PLC system was used as a new system to communicate several computers in a building. Then, the PLC communication reliability and transfer rate up to 1600 bps was developed. PLC communication can work in environments with unpredictable parameters and long distances (Nunn, 1997). Nowadays, this communication channel is used in high speed transfer called broad power line (BPL). The main advantage of PLC is availability of its infrastructures in electrical network. In addition, by the extended form of this network, all consumers, even at long distance, can be accessed. Therefore, it is cost effective. Its optimum frequency range of this channel is 70-160 KHz. But, there are some problems. Noise is considered as the main constraint (Abraham, 1992). The main recourses of noise are as follows: a) 50 Hz harmonics that cause maximum disturbance in high speed data transferring and mostly attenuate and become narrow band at frequencies more than 30 kHz. B) The background noise that generated by household equipments, c) burst noise caused by industrial loads. Generally, noise of PLC channel is reduced in higher frequencies. Loss and attenuation are the other constraints as well as signal dispersion. Signal provides by actual channel limitation like bandwidth limitations and non-linearity leading to delay distortion of signal. Automatic meter reading (AMR) is one of the fields that can be performed by PLC communication channel. In this paper an AMR system besides of the above constraints is described.
  • Keywords
    automatic meter reading; distortion; programmable controllers; AMR prototype system; PLC communication channel; PLC technology; automatic meter reading; broad power line; channel limitation; high speed data transferring; programmable controllers; signal dispersion; signal distortion; Automatic meter reading; Availability; Background noise; Communication channels; Costs; Frequency; Power line communications; Power system reliability; Programmable control; Prototypes; AMR; CSMA; PLC; polling;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Engineering Society General Meeting, 2007. IEEE
  • Conference_Location
    Tampa, FL
  • ISSN
    1932-5517
  • Print_ISBN
    1-4244-1296-X
  • Electronic_ISBN
    1932-5517
  • Type

    conf

  • DOI
    10.1109/PES.2007.385685
  • Filename
    4275294