• DocumentCode
    3095426
  • Title

    Speckle-enhanced cardiac blood flow imaging with high frame rate ultrasound

  • Author

    Takahashi, Hiroki ; Hasegawa, Hiroshi ; Kanai, Hiroshi

  • Author_Institution
    Grad. Sch. of Biomed. Eng., Tohoku Univ., Sendai, Japan
  • fYear
    2013
  • fDate
    21-25 July 2013
  • Firstpage
    2030
  • Lastpage
    2033
  • Abstract
    Blood flow imaging in echocardiography helps users to evaluate the pumping function of the human heart. As a typical method, color Doppler imaging has been widely used to obtain the information of intracardiac blood flow. Color Doppler imaging, however, does not show the direction of blood flow stream because only flow velocity along a scan line is estimated. Echocardiographic particle image velocimetry (E-PIV) technique gives flow characteristic information, such as velocity vector fields and stream lines of blood flow, which are calculated based on motions of ultrasonic echoes from contrast agent. However, E-PIV is an invasive approach forcing physical and mental burden on patients because of intravenous injection of a contrast agent. To overcome this problem, we propose a non-invasive method for cardiac blood flow imaging by visualization of motions of echoes from blood particles. High frame rate measurement by parallel receive beamforming with spherically diverging wave was used for continuous observation of echoes from the same blood particles between frames. In addition, a coded excitation with 5-bit Barker code and clutter filtering were also used to enhance weak echoes from blood particles. Moreover, the power of echo signal was weighted by coherence calculated from demodulated signals to suppress the random noise which remained after clutter filtering. Through in vivo measurement of a 26-year-old healthy male, B mode image overlaid with enhanced echo speckle of blood particle was obtained in the three chamber view. Moreover, velocity vectors of blood flow could be estimated by applying enhanced echoes of blood particles with speckle tracking technique. The estimated velocity vector showed that blood is flowed out to the aorta in systole and is flowed into the left ventricular cavity in diastole. The in vivo result shows a potential of non-invasive imaging of blood flow pattern at high temporal and spatial resolution using our proposed method.
  • Keywords
    Doppler measurement; blood flow measurement; blood vessels; cardiovascular system; echocardiography; image denoising; image motion analysis; image resolution; medical image processing; object tracking; pattern formation; random noise; speckle; 5-bit Barker code; B mode image; E-PIV; aorta; blood flow pattern; blood flow stream direction; blood flow stream lines; blood particle; clutter filtering; coded excitation; color Doppler imaging; contrast agent; demodulated signal; diastole; echo motion visualization; echo signal power; echocardiographic particle image velocimetry technique; echocardiography; enhanced echo speckle; estimated velocity vector; flow characteristic information; flow velocity; high frame rate measurement; high frame rate ultrasound; human heart; intracardiac blood flow; intravenous injection; left ventricular cavity; mental burden; noninvasive imaging; noninvasive method; parallel receive beamformation; physical burden; pumping function; random noise suppression; scan line; spatial resolution; speckle tracking technique; speckle-enhanced cardiac blood flow imaging; spherically diverging wave; systole; temporal resolution; three chamber view; ultrasonic echo motions; velocity vector field; weak echoes; Blood; Clutter; Imaging; Speckle; Ultrasonic imaging; Vectors; Visualization;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Ultrasonics Symposium (IUS), 2013 IEEE International
  • Conference_Location
    Prague
  • ISSN
    1948-5719
  • Print_ISBN
    978-1-4673-5684-8
  • Type

    conf

  • DOI
    10.1109/ULTSYM.2013.0518
  • Filename
    6724980