    A harmonic tracking method for improved visualization of arterial structures with acoustic radiation force impulse imaging

  • Author

    Doherty, Joshua R. ; Dahl, Jeremy ; Allen, Jason D. ; Ham, Katherine L. ; Trahey, Gregg E.

  • Author_Institution
    Dept. of Biomed. Eng., Duke Univ., Durham, NC, USA
  • fYear
    2013
  • fDate
    21-25 July 2013
  • Firstpage
    1769
  • Lastpage
    1772
  • Abstract
    Acoustic Radiation Force Impulse (ARFI) imaging has shown improved visualization of arterial structures that may provide for a more reliable assessment of atherosclerotic risk than conventional B-mode imaging. Existing ARFI imaging methods, however, are limited due to the presence of clutter that can increase bias and jitter in estimates of tissue deformation. We have recently developed a novel pulse inversion harmonic tracking method to suppress clutter degradation in ultrasonic tissue displacement estimates. In this work, harmonic B-mode and harmonic ARFI images of in vivo carotid arteries are compared with fundamental images obtained using conventional techniques. A certified reader measured the intima-media-thickness (IMT) in B-mode images and the adventitia-intima-media-thickness (AIMT) in ARFI images. The yield and the length of the artery amenable for analysis were larger in ARFI images compared to B-mode images. Intra-reader measurements of ARFI AIMT in the distal wall were more reproducible than B-mode IMT measurements. Qualitatively, harmonic ARFI images showed improved delineation of the vessel-lumen interface compared to fundamental ARFI images. These results suggest that harmonic ARFI imaging may provide a reliable method for monitoring arterial thickening to predict the occurrence of clinical events.
  • Keywords
    biomechanics; biomedical ultrasonics; blood vessels; cardiology; deformation; inverse problems; medical disorders; medical image processing; object tracking; ARFI AIMT measurement; ARFI imaging methods; B-mode IMT measurement; acoustic radiation force impulse imaging; adventitia-intima-media-thickness; arterial structure visualization; arterial thickening monitoring; artery length; artery yield; atherosclerotic risk assessment; bias; clinical event occurrence; clutter degradation; clutter presence; conventional B-mode imaging; distal wall; fundamental ARFI images; harmonic ARFI images; harmonic ARFI imaging; harmonic B-mode images; improved visualization; in vivo carotid arteries; intrareader measurements; jitter; pulse inversion harmonic tracking method; tissue deformation; ultrasonic tissue displacement estimates; vessel-lumen interface delineation; Acoustics; Arteries; Harmonic analysis; Imaging; Thickness measurement; Ultrasonic imaging; Ultrasonic variables measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Ultrasonics Symposium (IUS), 2013 IEEE International
  • Conference_Location
    Prague
  • ISSN
    1948-5719
  • Print_ISBN
    978-1-4673-5684-8
  • Type

    conf

  • DOI
    10.1109/ULTSYM.2013.0451
  • Filename
    6725080