DocumentCode
3097564
Title
Comparison of Three Front-end DC-DC Converters for 1200W Server Power Supply
Author
Li, Dong ; Ruan, Xinbo
Author_Institution
Coll. of Autom. Eng., Nanjing Univ. of Aeronaut. & Astronaut.
fYear
2005
fDate
16-16 June 2005
Firstpage
394
Lastpage
398
Abstract
Server power supply with universal input is composed of power factor correction (PFC) stage and front-end dc-dc stage. The output voltage of PFC stage varies with input voltage rms in order to improve the efficiency at low line. So it is important to select a dc-dc converter with wide input range. This paper proposes that a hybrid full-bridge three-level (HFB TL) converter is suitable for this application. The merits of this converter are low voltage stress of power semiconductor, small circulating energy and output filter inductor. The features of proposed converter are compared with the conventional phase-shift full-bridge (PS FB) dc-dc converter. The prototypes of two PS FB converters with different input range and HFB TL converter are built up to verify the analysis
Keywords
DC-DC power convertors; bridge circuits; power factor correction; power supplies to apparatus; 1200 W; PFC; circulating energy; front-end DC-DC converters; hybrid full-bridge three-level converter; output filter inductor; phase-shift full-bridge dc-dc converter; power factor correction; power semiconductor; server power supply; Active filters; Bridge circuits; DC-DC power converters; Inductors; Power factor correction; Power supplies; Stress; Switches; Switching converters; Zero voltage switching;
fLanguage
English
Publisher
ieee
Conference_Titel
Power Electronics Specialists Conference, 2005. PESC '05. IEEE 36th
Conference_Location
Recife
Print_ISBN
0-7803-9033-4
Type
conf
DOI
10.1109/PESC.2005.1581654
Filename
1581654
Link To Document