DocumentCode
3097591
Title
High-sensitivity distribution mapping of iron, zinc and copper during spio-microbubbles facilitated focused ultrasound induced blood-brain barrier opening via laser ablation/inductively coupled plasma mass spectrometry
Author
Ching-Hsiang Fan ; Yi-Kong Hsieh ; Chien-Yu Ting ; Hao-Li Liu ; Chu-Fang Wang ; Chih-Kuang Yeh
Author_Institution
Dept. of Biomed. Eng. & Environ. Sci., Nat. Tsing Hua Univ., Hsinchu, Taiwan
fYear
2013
fDate
21-25 July 2013
Firstpage
2092
Lastpage
2095
Abstract
Focused ultrasound (FUS) with microbubbles (MBs) has been approved to achieve local blood-brain barrier disruption (BBBD), increasing the delivery of therapeutic agents into brain. Previous reports have demonstrated the use of medical imaging system (ultrasound, CT, MRI, SPECT, or PET) to observe the redistribution of the delivered substance. However, the redistribution of elements such as zinc or copper has not yet been discovered, nor their effects and roles to CNS after FUS sonications. Laser ablation/inductively coupled plasma mass spectrometry (LA-ICP-MS) is a sensitive analytical technique and is capable of quantitatively providing solid inorganic matrices distribution in tissues. In this study, LA-ICPMS was used to explore the feasibility of detecting the delivered iron (i.e. SPIO-conjugated MBs, SPIO-MBs) and its redistribution after magnetic targeting (MT), as well as the elements redistribution. The 1-MHz FUS (acoustic energy = 0.4-1.0 MPa, duty cycle = 10%, sonication time = 1 min) was exposed to left brain of rats following SPIO-MBs injection to induce BBBD (SPIO payload was 200 ± 19.6 μg by ICP-AES). A 0.5 T permanent magnet was attached to the rat´s scalp for performing MT. The spatial elemental maps were performed with the LA-ICP-MS system excited by 213 nm Nd-YAG laser (energy = 1.6 mJ, frequency = 10 Hz, scanning speed = 90 μm/s). The distribution and concentration of elements including iron, copper, and zinc were analyzed. Results showed that LA-ICPMS performed high sensitivity in the detection of the elements distribution in the brain. The iron mapping revealed that SPIOs were highly concentrated at FUS exposed and MT performed sites. No obvious zinc and copper deposition within sonication regions were found after FUS sonication. This study confirmed the potential of LA-ICP-MS for providing highly-sensitive detection method for solid inorganic matrices in brain tissues, and tracing the redistribution of elements. Moreover- concurrent use of SPIO-MBs with MT further enhanced the SPIO delivery into the BBBD area. Future work includes using SPIO-MBs as a surrogate tracer to estimate drug delivery efficiency during BBBD.
Keywords
biological tissues; biomedical ultrasonics; blood; brain; copper; iron; laser ablation; laser applications in medicine; mass spectroscopy; neurophysiology; permanent magnets; ultrasonic imaging; zinc; Cu; FUS sonications; Fe; LA-ICP-MS system; SPIO delivery; SPIO-microbubbles; Zn; acoustic energy; brain tissues; copper; drug delivery efficiency; element redistribution; focused ultrasound induced blood-brain barrier opening; focused ultrasound microbubbles; frequency 1 MHz; high-sensitive detection method; high-sensitivity distribution mapping; iron mapping; laser ablation-inductively coupled plasma mass spectrometry; magnetic flux density 0.5 T; magnetic targeting; medical imaging system; permanent magnet; rat scalp; sensitive analytical technique; solid inorganic matrices; spatial elemental maps; therapeutic agents; tissue distribution; wavelength 213 nm; zinc; Biology; Biomedical imaging; Cameras; Iron; Software; Ultrasonic variables measurement; Laser ablation/inductively coupled plasma mass spectrometry; blood-brain barrier; focused ultrasound; superparamagnetic iron oxide;
fLanguage
English
Publisher
ieee
Conference_Titel
Ultrasonics Symposium (IUS), 2013 IEEE International
Conference_Location
Prague
ISSN
1948-5719
Print_ISBN
978-1-4673-5684-8
Type
conf
DOI
10.1109/ULTSYM.2013.0534
Filename
6725095
Link To Document