• DocumentCode
    3097979
  • Title

    4-D echocardiography assessment of local myocardial strain using 3-D speckle tracking combined with shape tracking

  • Author

    Wong, Emily Y. ; O´Donnell, Matthew ; Thiele, Karl ; Compas, Colin B. ; Huang, Xumin ; Sampath, Smita ; Lin, Ben A. ; Pal, Parama ; Papademetris, Xenios ; Dione, Donald ; Staib, Lawrence ; Sinusas, Albert J. ; Duncan, James S.

  • Author_Institution
    Dept. of Bioeng., Univ. of Washington, Seattle, WA, USA
  • fYear
    2013
  • fDate
    21-25 July 2013
  • Firstpage
    100
  • Lastpage
    103
  • Abstract
    In 4-D echocardiography (4DE), displacement estimates obtained solely from multi-dimensional speckle tracking can exhibit large variances and peak hopping, making it challenging to accurately calculate myocardial strains. 3-D phase-sensitive speckle tracking can produce sensitive estimates along the axial direction, but typically provides poorer estimates in orthogonal directions and at tissue boundaries. Shape tracking provides complimentary information, as it effectively tracks myocardial boundaries and does not depend on beam orientation. We propose a method combining 3-D speckle tracking with 3-D shape tracking using a quality-based radial basis function approach. Echocardiographic data (3D+t) were acquired in an open chest canine model at six weeks following surgical coronary occlusion using a commercial 2-D phased array, on which 3-D phase-sensitive speckle tracking and 3-D shape tracking were performed. An adaptive, multi-level radial basis function method was used to combine information from the two tracking methods, utilizing confidence metrics to weight the contribution of each estimate to generate a dense 3-D displacement field throughout the myocardium. A multi-level approach was used to capture smaller scales of motion in regions of fine deformation variation and high tracking confidence. The 3-D combined approach produced displacement estimates with greatly reduced variance and peak hopping compared to 3-D speckle tracking alone. Lower radial strains were observed in the myocardial infarct region, corresponding to reduced local contractility. Strong correlations were observed for both radial and circumferential strains between the combined method and estimates from magnetic resonance (MR) tagging studies.
  • Keywords
    biomechanics; deformation; diseases; echocardiography; edge detection; functions; medical image processing; motion estimation; muscle; object tracking; shape recognition; speckle; ultrasonic arrays; veterinary medicine; 3D phase-sensitive speckle tracking; 3D shape tracking; 4D echocardiography assessment; MR tagging studies; adaptive multilevel radial basis function method; beam orientation dependence; circumferential strains; commercial 2D phased array; confidence metrics; dense 3D displacement field generation; displacement estimation peak hopping; displacement estimation variance; echocardiographic data acquisition; fine deformation variation; high tracking confidence; local contractility reduction; local myocardial strain calculation; magnetic resonance tagging studies; multidimensional speckle tracking; myocardial boundary tracking; myocardial infarct region; open chest canine model; quality-based radial basis function approach; radial strains; small scale motion capture; surgical coronary occlusion; time 6 week; tissue boundaries; tracking information combination; Correlation; Myocardium; Shape; Speckle; Strain; Tracking; Ultrasonic imaging; confidence index; echocardiography; motion estimation; shape tracking; speckle tracking;
  • fLanguage
    English