Title :
In vivo three-dimensional velocity vector imaging and volumetric flow rate measurements
Author :
Pihl, Michael Johannes ; Stuart, Matthias Bo ; Tomov, Borislav G. ; Hanseny, Peter Moller ; Nielseny, Michael Bachmann ; Jensen, John A.
Author_Institution :
Dept. of Elec. Eng., Tech. Univ. of Denmark, Lyngby, Denmark
Abstract :
The three-dimensional (3-D) Transverse Oscillation (TO) method is used to obtain 3-D velocity vector estimates in two orthogonal planes. The method is suitable for a real-time implementation. Data are acquired using a Vermon 3.0 MHz 32×32 element 2-D phased array and the experimental ultrasound scanner SARUS. Measurements are conducted on a carotid artery flow phantom from Danish Phantom Design, and 20 frames are acquired with a constant flow rate of 16.7±0.17 mL/s provided by a Shelley Medical Imaging Technologies CompuFlow 1000 system. The peak velocity magnitude in the vessel is found to be 52.3±8.1 m/s compared to an expected peak velocity of 53.6±0.54 cm/s. Based on the out-of-plane velocity component in the cross-sectional plane, the estimated volumetric flow rates are 17.1±1.4 mL/s. The coefficient of variation is 8.3%, and the bias is 2.2%. An in vivo measurement of 3-D M-mode velocities is conducted over five heart beats. The peak systolic and end-diastolic velocities are 69±5.4 cm/s and 7.9±5.5 cm/s at the center of the vessel. For comparison, a commercial BK Medical ultrasound scanner using the spectral estimator yields 71.2 cm/s and 7.70 cm/s, respectively. The results demonstrate that the 3-D TO method can estimate 3-D velocities in two crossed planes, volumetric flow rates, and 3-D velocities in vivo.
Keywords :
blood flow measurement; blood vessels; flow visualisation; phantoms; velocity measurement; 3D M-mode velocity measurement; 3D transverse oscillation method; 3D velocity vector estimates; 3D velocity vector imaging measurement; BK Medical ultrasound scanner; Danish Phantom Design; Shelley Medical Imaging Technologies CompuFlow 1000 system; Vermon 2D phased array; carotid artery flow phantom; cross-sectional plane; crossed planes; end-diastolic velocity; frequency 3 MHz; heart beats; orthogonal planes; out-of-plane velocity component; peak systolic velocity; peak velocity magnitude; spectral estimator; ultrasound scanner SARUS; variation coefficient; vessel center; volumetric flow rate measurement; Carotid arteries; Estimation; Imaging; In vivo; Ultrasonic imaging; Ultrasonic variables measurement; Vectors;
Conference_Titel :
Ultrasonics Symposium (IUS), 2013 IEEE International
Conference_Location :
Prague
Print_ISBN :
978-1-4673-5684-8
DOI :
10.1109/ULTSYM.2013.0019