DocumentCode :
3099845
Title :
Power Management in a Biotelemetry Application
Author :
Sun, C.C. ; Dunford, W.G.
Author_Institution :
Dept. of Electr. & Comput. Eng., British Columbia Univ., Vancouver, BC
fYear :
2005
fDate :
16-16 June 2005
Firstpage :
1182
Lastpage :
1190
Abstract :
Power management for a biotelemetry tag implanted into the body of a sealion with the body temperature around 40degC is described. Various types of batteries are considered, possibly in combination with a supercapacitor. Component test results are used to predict the tag life time
Keywords :
biomedical telemetry; condition monitoring; load management; batteries; biotelemetry application; power management; supercapacitor; tag life time prediction; Base stations; Batteries; Biomedical telemetry; Energy management; Low-noise amplifiers; Microcontrollers; Monitoring; Temperature; Topology; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power Electronics Specialists Conference, 2005. PESC '05. IEEE 36th
Conference_Location :
Recife
Print_ISBN :
0-7803-9033-4
Type :
conf
DOI :
10.1109/PESC.2005.1581779
Filename :
1581779
Link To Document :
بازگشت