DocumentCode
3100964
Title
Ultrasonically marked instruments for ultrasound-guided interventions
Author
Mung, Jay ; Vignon, Francois ; Erkamp, Ramon ; Stanton, Doug ; Jain, Abhishek
Author_Institution
Sinc Labs., LLC, Los Angeles, CA, USA
fYear
2013
fDate
21-25 July 2013
Firstpage
2053
Lastpage
2056
Abstract
In order to enhance needle and catheter visibility under ultrasound and enable tool tracking, it has been proposed to embed ultrasound receivers near the tip of interventional tools. Using these sensors to receive and analyze signals coming from the imaging probe as its beams sweep the field of view, the position of the sensor can be estimated with <;0.5mm accuracy even when the tool tip is invisible in the pulse-echo image. One crucial design parameter for these ultrasonically marked instruments is the sensitivity and directivity pattern of the sensor: the ideal sensor has to maintain adequate SNR at a wide range of depths and insonification angles depending on the clinical intervention. This paper presents the acoustical characterization of small (~1mm) high frequency (>10MHz) PZT sensors in different form factors for acoustical marking of needles and catheters. PZT-equipped tools including guidewires, steerable sheaths, and biopsy needles are also presented and the tracking capability is demonstrated ex vivo. Maximum SNRs of >50dB were found with all sensors in the water tank at an imaging depth of 8cm and insonification MI of 1.1. Complex directivity patterns were observed varying with sensor size and shape, likely owing to mode conversion inside the sensor and excitation of the materials´ transverse piezoelectric modes. Small disks (≤1mm diameter) were found to be most appropriate with flattest directivity. Ex vivo experiments demonstrated reliable tracking of an ultrasound-equipped needle at depths >10cm. In conclusion, it is feasible to manufacture PZT-equipped instruments exhibiting good tracking accuracy and robustness.
Keywords
biomedical transducers; biomedical ultrasonics; medical image processing; needles; piezoelectric transducers; sensors; tracking; PZT-equipped instruments; acoustical characterization; biopsy needles; catheter visibility enhancement; depth 8 cm; guidewires; high frequency PZT sensors; imaging depth; insonification angles; material transverse piezoelectric mode excitation; needle visibility enhancement; pulse-echo image; signal analysis; signal-to-noise ratio; steerable sheaths; ultrasonically marked instruments; ultrasound receivers; ultrasound-equipped needle tracking; ultrasound-guided interventions; water tank; Catheters; Imaging; Needles; Probes; Sensor phenomena and characterization; Ultrasonic imaging; PZT; Tool tracking; device; intervention; navigation;
fLanguage
English
Publisher
ieee
Conference_Titel
Ultrasonics Symposium (IUS), 2013 IEEE International
Conference_Location
Prague
ISSN
1948-5719
Print_ISBN
978-1-4673-5684-8
Type
conf
DOI
10.1109/ULTSYM.2013.0524
Filename
6725259
Link To Document