• DocumentCode
    3104924
  • Title

    Thermal Performance of a Three-Phase Induction Motor Under Fault Tolerant Operating Strategies

  • Author

    Mendes, A.M.S. ; Lopez-Fernandez, Xose M. ; Cardoso, A. J Marques

  • Author_Institution
    DEEC, Coimbra Univ.
  • fYear
    2005
  • fDate
    16-16 June 2005
  • Firstpage
    2886
  • Lastpage
    2892
  • Abstract
    This paper presents the thermal behaviour of a three-phase induction motor under direct torque control, when supplied by a three-phase voltage source inverter with fault tolerant capabilities. For this purpose, a fault tolerant operating strategy based on the connection of the faulty inverter leg to the DC link middle point was considered. The motor thermal profile is obtained through the use of nine thermocouples positioned in both stator and rotor circuits. The experimental results obtained under fault compensated operation show that, as far as the motor thermal characteristics are concerned, it is not necessary to reinforce the motor insulation properties since it is already prepared for such an operation
  • Keywords
    fault tolerance; induction motors; invertors; machine control; rotors; stators; thermocouples; torque control; direct torque control; fault tolerant operating strategies; faulty inverter leg; motor insulation; motor thermal profile; rotor circuits; stator circuits; thermal performance; thermocouples; three-phase induction motor; three-phase voltage source inverter; Circuit faults; Fault tolerance; Frequency conversion; Induction motors; Insulation; Inverters; Rotors; Stator windings; Temperature; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Electronics Specialists Conference, 2005. PESC '05. IEEE 36th
  • Conference_Location
    Recife
  • Print_ISBN
    0-7803-9033-4
  • Type

    conf

  • DOI
    10.1109/PESC.2005.1582043
  • Filename
    1582043