• DocumentCode
    3111125
  • Title

    Matching a pulsed power modulator to a corona plasma reactor

  • Author

    Winands, G.J.J. ; Pemen, A.J.M. ; van Heesch, E.J.M. ; Liu, Z. ; Yan, K.

  • Author_Institution
    Eindhoven University of Technology, Dept. of Electrical Engineering, P.O.Box 513, 5600 MB Eindhoven, Netherlands
  • Volume
    1
  • fYear
    2007
  • fDate
    17-22 June 2007
  • Firstpage
    587
  • Lastpage
    590
  • Abstract
    In this paper, the matching between the a pulsed power modulator and a corona plasma reactor is discussed. The matching is expressed as the energy transfer efficiency between the modulator and the reactor. The criterion for optimal matching between a source and a load is that the output impedance of the source is equal to the load impedance. When trying to match a pulsed power modulator to a plasma reactor this criterion is difficult to obey since the load impedance changes rapidly before, during and after plasma generation. To simulate the response of the load as function of the voltage pulse, an equivalent circuit is used. Measurements will be presented to verify the derived model. Guidelines to optimize the matching between the modulator and reactor are derived.
  • Keywords
    Corona; Energy exchange; Impedance; Inductors; Optimal matching; Plasma measurements; Plasma simulation; Plasma sources; Power generation; Pulse modulation;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Pulsed Power Conference, 2007 16th IEEE International
  • Conference_Location
    Albuquerque, NM
  • Print_ISBN
    978-1-4244-0913-6
  • Electronic_ISBN
    978-1-4244-0914-3
  • Type

    conf

  • DOI
    10.1109/PPPS.2007.4651911
  • Filename
    4651911