DocumentCode :
3113599
Title :
Thermal field study and analysis in hybrid solar flue gas chimney power plant
Author :
Chikere, Aja Ogboo ; Alkayiem, Hussain H. ; Karim, Zainal Ambri Abdul
Author_Institution :
Mech. Eng. Dept., Univ. Teknol. PETRONAS, Tronoh, Malaysia
fYear :
2011
fDate :
19-20 Sept. 2011
Firstpage :
1
Lastpage :
6
Abstract :
The concept of using flue gas waste heat as a backup in a solar chimney power plant is driven by the objective of solar chimney plant performance enhancement. This paper presents experimental results of thermal field of hybrid solar-flue-gas chimney power plant at different mode (solar mode, hybrid mode and flue gas mode). The experimental test rig consisted of two inclined absorber plate and diffuser surface with total area of 3.15 m2, flue gas channel (1m × 3m × 0.05m), greenhouse (air flow channel of 1m × 3m × 0.16m at inlet and 1m × 3m × 0.075m at exit), chimney of diameter 0.15m and height of 4m, flue gas inlet diffuser (1m × 0.3m × 0.05m) and flue-gas source (biomass burner coupled with centrifugal blower powered using a variable speed motor). The temperature distribution in the hybrid solar-flue gas chimney power plant test-rig was measured. Temperature difference between the chimney base (absorber plate exit air) and the ambient were studied which is the driving force in solar chimney power plant. On solar mode, the driving force (temperature difference between the absorber plate exit air and the ambient air) gave a maximum ΔT of 27.6 °C at irradiance of 797 W/m2. With flue gas as thermal backup during the day, maximum ΔT reached 38.1°C for inlet flue-gas temperature of 101.6 °C and irradiance of 672 W/m2, with flue gas as the only source of thermal energy (night mode), the temperature difference, ΔT, got up to 25.9 °C at a flue-gas inlet temperature of 107.6 °C. The solar mode experiment carried out after night mode experiment shows that the ΔT of the system the next day was enhanced as the temperature difference increased from sunrise contrary to the low temperature raise experienced on normal solar day.
Keywords :
flue gases; solar absorber-convertors; solar power stations; temperature distribution; waste heat; waste-to-energy power plants; diffuser surface; driving force; flue gas channel; flue gas inlet diffuser; flue gas waste heat; greenhouse; hybrid solar flue gas chimney power plant analysis; hybrid solar-flue gas chimney power plant test-rig; inclined absorber plate; night mode experiment; size 0.15 m; solar chimney plant performance enhancement; solar mode experiment; temperature 101.6 degC; temperature 107.6 degC; temperature 27.6 degC; temperature 38.1 degC; temperature distribution; thermal energy source; thermal field study; Hybrid power systems; Solar heating; Solar radiation; Temperature measurement; Turbines; Waste heat; Flue-gas waste heat; Solar chimney; hybrid system; temperature field;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
National Postgraduate Conference (NPC), 2011
Conference_Location :
Kuala Lumpur
Print_ISBN :
978-1-4577-1882-3
Type :
conf
DOI :
10.1109/NatPC.2011.6136401
Filename :
6136401
Link To Document :
بازگشت