Abstract :
In this paper the susceptibility of synchronous rectified step-down converters to electromagnetic interference (100 kHz - 500 MHz) is examined and evaluated by experimental measurements. Performance degradation of linear low dropout regulators due to RF rectification and non-linear effects of RFI on error amplifiers is well documented. SR buck converters exhibit system stability and poor transient response behavior due to low-level RF injection and a complete circuit failure operation in presence of high-level RF injection. The use of L-C filter for RFI solution must be designed carefully as it can degrade the converterpsilas transient response.
Keywords :
electromagnetic interference; filters; power convertors; rectifying circuits; stability; transient response; EMI; LC filter; RF rectification; buck converters; circuit failure operation; electromagnetic interference; error amplifiers; frequency 100 kHz to 500 MHz; high-level RF injection; linear low dropout regulators; nonlinear effects; synchronous rectified step-down converter; system stability; transient response; Buck converters; Degradation; Electromagnetic interference; Electromagnetic measurements; Radio frequency; Radiofrequency amplifiers; Radiofrequency interference; Regulators; Strontium; Transient response; Direct RF Injection (DRFI); Phase Margin; Rectification; Synchronous Rectified Step-Down Converter; TEM Cell. Compensation;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electromagnetic Compatibility, 2008. EMC 2008. IEEE International Symposium on
Conference_Location :
Detroit, MI
Print_ISBN :
978-1-4244-1699-8
Electronic_ISBN :
978-1-4244-1698-1
Type :
conf
DOI :
10.1109/ISEMC.2008.4652080
Filename :
4652080
Link To Document :
بازگشت