  • Abstract
    Phenomena taking place into an electromagnetic shield are complex (absorption, reflection, transmission). They are determined by material/shield macroscopic parameters (epsiv, mu, sigma), its thickness, radiationpsilas frequency and incidence angle. The paper deals with an original method for visualization and measurement of shielding effectiveness. This method has the advantage of simplicity and validates for the first time theoretical predictions as opposed to TEM cell method based on mathematical isomorphism (infinite plane shield vs. coaxial transmission lines). Even if it is formally accurate, it has not been experimentally validated up to present, in the area of electrically thick samples, according to many works in the field.
  • Keywords
    TEM cells; electromagnetic shielding; SEdB determination; TEM cell method; electromagnetic shield; incidence angle; material-shield macroscopic parameters; mathematical isomorphism; radiation frequency; shielding effectiveness; Coaxial components; Electromagnetic measurements; Electromagnetic radiation; Electromagnetic reflection; Electromagnetic shielding; Electromagnetic wave absorption; Frequency; TEM cells; Transmission line measurements; Visualization; Shielding effectiveness; TEM cell; antennas; radiation pattern;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electromagnetic Compatibility, 2008. EMC 2008. IEEE International Symposium on
  • Conference_Location
    Detroit, MI
  • Print_ISBN
    978-1-4244-1699-8
  • Electronic_ISBN
    978-1-4244-1698-1
  • Type

    conf

  • DOI
    10.1109/ISEMC.2008.4652089
  • Filename
    4652089