Abstract :
Insulated motor windings arrive at motor shops in various states of cleanliness, age, and damage. The authors describe the typical tests and procedures applied in EASA (Electrical Apparatus Service Association) shops to check the old insulation system, and the new winding insulation if required. The results of a survey taken in the Southeastern Chapter of the EASA are used to illustrate the range of capabilities and procedures. Repair tests on a typical three-phase, AC induction motor are described. Many comments also apply to wound rotor and DC motors. Of the shops surveyed, 63% had the capability of fully testing 4-kV insulation. All (98%) could test 600-V insulation. It is noted that AC ground testing is potentially hazardous to windings if it is applied by touching the leads and drawing an arc. Similarly, faulty contacts in motor starting can cause high voltage transients. The magnitude of the winding-to-ground capacitance is an important factor in insulation stress during motor starting
Keywords :
insulation testing; machine insulation; machine testing; machine windings; 4 kV; 600 V; AC ground testing; DC motors; EASA; Electrical Apparatus Service Association; age; arc drawing; cleanliness; damage; faulty contacts; high voltage transients; insulated motor windings; insulation stress; insulation stressing; motor repair shop testing; motor starting; new winding insulation; old insulation system; range of capabilities; range of procedures; repair tests; survey; three-phase AC induction motor; winding hazards; winding-to-ground capacitance; wound rotor; Capacitance; DC motors; Dielectrics and electrical insulation; Induction motors; Insulation testing; Rotors; Stress; System testing; Voltage; Wounds;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Electronics Insulation Conference, 1989. Chicago '89 EEIC/ICWA Exposition., Proceedings of the 19th
Conference_Location :
Chicago, IL
Type :
conf
DOI :
10.1109/EEIC.1989.208202
Filename :
208202
Link To Document :
بازگشت