DocumentCode :
3117526
Title :
Voltage stresses in three-phase, A-C motors
Author :
Anderson, James J.
Author_Institution :
Electr. Mech. Services, St. Paul, MN, USA
fYear :
1989
fDate :
25-28 Sep 1989
Firstpage :
115
Lastpage :
116
Abstract :
Winding failures on large AC motors (100 HP and up) have been reported in increasing numbers recently by repair shops throughout the country. Although these reports involve equipment operated in varying circumstances, the evidence suggests that voltage stress on the windings has been a major cause of such failures. The author examines the kinds of voltage stress that occur in large AC motors and outlines steps that can be taken to prevent the windings from failing prematurely. It is emphasized that it is necessary to be very careful in large random-wound motors to keep the voltage per coil as low as possible in the type of connection used, and to place the turns in the slots so that they are as evenly distributed as possible. The connection and coil design should be such as not to exceed 30 V per turn
Keywords :
AC motors; machine windings; 100 hp; 30 V; coil design; large AC motors; large random-wound motors; premature failure; repair shops; rewinding machines; slot turns; three-phase AC motors; voltage per coil; voltage stress; winding failures; Cable insulation; Coatings; Coils; Conductors; Glass; Manufacturing processes; Stress; Testing; Voltage; Wire;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Electronics Insulation Conference, 1989. Chicago '89 EEIC/ICWA Exposition., Proceedings of the 19th
Conference_Location :
Chicago, IL
Type :
conf
DOI :
10.1109/EEIC.1989.208204
Filename :
208204