• DocumentCode
    3119404
  • Title

    Absolute Optical Frequency Measurements with a Fractional Frequency Uncertainty at 1 Ã\x97 10-15

  • Author

    Stalnaker, J.E. ; Diddams, S.A. ; Kim, K. ; Hollberg, L. ; Donley, E.A. ; Heavner, T.P. ; Jefferts, S.R. ; Levi, F. ; Parker, T.E. ; Bergquist, J.C. ; Itano, W.M. ; Jensen, M.J. ; Lorini, L. ; Oskay, W.H. ; Fortier, T.M.

  • Author_Institution
    Time & Frequency Div., National Inst. of Stand. & Technol., Boulder, CO
  • fYear
    2006
  • fDate
    4-7 June 2006
  • Firstpage
    462
  • Lastpage
    469
  • Abstract
    We report the technical details specific to our recent measurements of the optical frequency of the mercury single-ion frequency standard in terms of the SI second as realized by the NIST-F1 cesium fountain clock. In these measurements the total fractional uncertainty is ap 10-15, limited by the statistical measurement uncertainty. In this paper we will address the techniques employed for the optical-to-microwave comparison itself, which had an estimated fractional uncertainty of ap 3 times 10-16, limited by the stability of the electronics used for the comparison
  • Keywords
    frequency standards; measurement uncertainty; cesium fountain clock; fractional frequency uncertainty; frequency standard; mercury single ion; optical frequency measurements; statistical measurement uncertainty; Frequency conversion; Frequency measurement; Frequency synthesizers; Hydrogen; Laboratories; Masers; Measurement standards; Optical frequency conversion; Particle beam optics; Ultrafast optics;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    International Frequency Control Symposium and Exposition, 2006 IEEE
  • Conference_Location
    Miami, FL
  • Print_ISBN
    1-4244-0074-0
  • Electronic_ISBN
    1-4244-0074-0
  • Type

    conf

  • DOI
    10.1109/FREQ.2006.275430
  • Filename
    4053808