DocumentCode
3119680
Title
Development of a performance test system for evaluation of automatic tank gauging system
Author
Lee, Sangil ; Kim, Hyun Ho ; Choi, Hae Man
Author_Institution
Korea Res. Inst. of Stand. & Sci., Daejeon, South Korea
fYear
2011
fDate
Nov. 28 2011-Dec. 1 2011
Firstpage
323
Lastpage
324
Abstract
A performance test system was developed to evaluate automatic tank gauging system (ATGS) that detects leakage from underground storage tanks. The performance test system consists of assessments of the accuracy and repeatability and the leak detection capability of the ATGS. The target accuracy, repeatability, and leak detection capability is 0.04, 0.01, and 0.04 mm, respectively. After the development of the performance test system, a newly designed ATGS was evaluated using the system.
Keywords
gauges; leak detection; performance evaluation; soil; tanks (containers); ATGS; automatic tank gauging system; leakage detection; performance test system; underground storage tanks; Accuracy; Atmospheric measurements; Contamination; Leak detection; Probability; Soil; Storage tanks; automatic tank gausing system (ATGS); soil contamination; underground storage tank;
fLanguage
English
Publisher
ieee
Conference_Titel
Sensing Technology (ICST), 2011 Fifth International Conference on
Conference_Location
Palmerston North
ISSN
2156-8065
Print_ISBN
978-1-4577-0168-9
Type
conf
DOI
10.1109/ICSensT.2011.6136992
Filename
6136992
Link To Document