    Cygnus trigger system

  • Author

    Nelson, D. ; Ormond, E. ; Cordova, S. ; Molina, I. ; Smith, J. ; Corrow, G. ; Hansen, M. ; Henderson, D. ; Mitton, C.

  • Author_Institution
    Sandia National Laboratories, PO Box 5800, Mail Stop 1176, Albuquerque, NM 87185-1193 USA
  • Volume
    2
  • fYear
    2007
  • fDate
    17-22 June 2007
  • Firstpage
    1313
  • Lastpage
    1318
  • Abstract
    The Cygnus Dual Beam Radiographic Facility consists of two radiographic sources (Cygnus 1, Cygnus 2) each with a dose rating of 4 rads at 1 m, and a 1-mm diameter spot size. The electrical specifications are: 2.25 MV, 60 kA, 60 ns. This facility is located in an underground environment at the Nevada Test Site (NTS). These sources were developed as a primary diagnostic for subcritical tests, which are single-shot, high-value events. In such an application there is an emphasis on reliability and reproducibility. A robust, low-jitter trigger system is a key element for meeting these goals. The trigger system was developed with both commercial and project-specific equipment. In addition to the traditional functions of a trigger system there are novel features added to protect the investment of a high-value shot. Details of the trigger system, including elements designed specifically for a subcritical test application, will be presented. The individual electronic components have their nominal throughput, and when assembled have a system throughput with a measured range of jitter. The shot-to-shot jitter will be assessed both individually and in combination. Trigger reliability and reproducibility results will be presented for a substantial number of shots executed at the NTS.
  • Keywords
    Assembly systems; Electronic components; Investments; Jitter; Protection; Radiography; Reproducibility of results; Robustness; System testing; Throughput;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Pulsed Power Conference, 2007 16th IEEE International
  • Conference_Location
    Albuquerque, NM
  • Print_ISBN
    978-1-4244-0913-6
  • Electronic_ISBN
    978-1-4244-0914-3
  • Type

    conf

  • DOI
    10.1109/PPPS.2007.4652429
  • Filename
    4652429