DocumentCode
3119880
Title
A bipolar Marx generator for a mobile electroporation device
Author
Sack, M. ; Stängle, R.
Author_Institution
Forschungszentrum Karlsruhe GmbH, Institute for Pulsed Power and Microwave Technology, P.O. Box 3640, 76021 Karlsruhe, Germany
Volume
2
fYear
2007
fDate
17-22 June 2007
Firstpage
1319
Lastpage
1322
Abstract
Since 2000 a mobile electroporation device has been operated for scientific and testing purposes. Now a breakdown of the insulation at one Marx generator output to ground has occurred due to an electric overstressing. This failure makes a redesign of the Marx generator necessary. For the redesign a bipolar Marx generator with a transient insulation to ground has been compared to one with a fixed center ground connection. The paper describes why the solution with the fixed ground connection is considered to be more suitable for the application in the mobile electroporation device.
Keywords
Electrodes; Inductors; Insulation; Microwave technology; Power generation; Pulse generation; Sugar industry; Testing; Throughput; Voltage;