DocumentCode
3120684
Title
A contribution to predicting the performances of district heating steam turbines at off-design conditions
Author
Gutesa, Milana
Author_Institution
Fac. of Tech. Sci., Univ. of Novi Sad, Novi Sad, Serbia
fYear
2013
fDate
6-8 June 2013
Firstpage
1
Lastpage
6
Abstract
This paper presents an approach to the development of the method for predicting the performances of CHP steam turbo-generators at design and off-design conditions. As the basis is used the method developed by General Electric engineers for condensing steam turbines. The method is up to dated for contemporary steam turbines and adapted for frequency of 50Hz. After the implementation of the necessary adoptions the efficiency calculation for low pressure CHP turbine is made and the results are compared to the results obtained from the turbine manufacturer.
Keywords
cogeneration; heating; steam turbines; turbogenerators; CHP steam turbo-generators; General Electric engineers; district heating steam turbines; frequency 50 Hz; off-design conditions; Cogeneration; Entropy; Equations; Generators; Production; Turbines; CHP steam turbine; Efficiency calculation; Off-design conditions; Performance predicting;
fLanguage
English
Publisher
ieee
Conference_Titel
Energy (IYCE), 2013 4th International Youth Conference on
Conference_Location
Sio??fok
Type
conf
DOI
10.1109/IYCE.2013.6604201
Filename
6604201
Link To Document